User Guide — Fire Extinguisher Simulator
1 Overview

The Fire Extinguisher Simulator is a workshop with a fire point of 12 extinguishers on the wall (11 types and a fire blanket) and 10 fires to deal with: wood and paper by the workbench, a solvent tray, a leaking gas cylinder, magnesium swarf in a lathe, a distribution board, a deep-fat fryer, an e-bike battery, a power-tool battery on charge, and two fires that are already too big to fight. Each extinguisher acts on each fire the way its agent really does: the right one puts the fire out, a weak one leaves embers that re-ignite, and a dangerous one makes it worse.

2 Train: do the drill yourself

Pick a fire. A coach in the panel takes you through the drill one step at a time, saying what to do and why, and what to press glows in the room. Raise the alarm turns to the call point by the exit: in the US you lift the clear cover of the pull station and pull the handle down; in the UK and Europe you press the call point's element in and its flag shows. The sounder above it then flashes and rings. Size up the fire shows you the fire with its size, then your way out drawn on the floor, then whether its supply can be shut off. To choose, the coach names the fire's class and the extinguishers that suit it, and Open the selection chart shows every extinguisher against every fire with this one's column marked; press a square to see why. Read the label, check the gauge, pull the pin and test-squirt, then Go to the fire and Walk into reach: the green band on the floor is where to stand with that extinguisher. The ring on the floor shows where the stream will land: green on the base of the fire, amber on the flames or its edge, grey when you are too far. Hold Squeeze (or Space) and drag left and right to sweep the whole base. Once it is out, watch it for 10 seconds, then back away facing it. Drag to aim (or A and D to turn and R and F to raise and lower the nozzle), and W and S step in and back. The debrief scores each step and Print practice summary gives you a record of the run.

3 Show me how

A trainer does the whole drill for the fire you picked, with a caption for each step and the camera following the action. Play, pause, step back and forward (or Space and the arrow keys) and drag the scrubber to any moment. Tick Show me the mistake to watch one of the 10 mistake clips: the common wrong choice for that fire, such as water on a burning fryer, and what it does.

4 How it works

How it works cuts an extinguisher in half so you can see inside: the agent, the nitrogen above it, the dip tube, the valve with its seal, spring and stem, the lever, the pin, the gauge and the hose. Pull the pin (click it, or the button), then hold the lever (press and hold it in 3D, hold the button, or hold Space) and watch the gas push the agent up the dip tube and out of the nozzle. Let go and the valve snaps shut. Hold it until it is empty and the plot shows the pressure falling as the gas expands. The readings give the pressure, the agent left, the flow and the force on your hand. Choose any extinguisher; the powders can also be shown cartridge-operated, and CO₂ is shown as the liquid under its own vapour pressure. The page opens here.

5 Quiz: Practical, Theory or Mixed

The Quiz starts with a choice. Practical is 5 questions in the workshop with no hints: 3 ask for the right first action for a fire (click it in the room or pick it from the list, and the reason follows), and 2 are whole drills you do on your own, from the alarm to backing away, passed or failed on the same scoring as Train. Theory asks 10 questions from a 25-question pool, written for the region you choose. Mixed is 5: 1 drill, 2 first-action questions and 2 theory questions.

6 Regions, units and sound

US · NFPA 10 and UK & Europe · BS EN 3 change the labels, class letters, colour bands and rules to the ones you will meet at work; the fire behaves the same. SI and Imperial change the units. Sound is synthesised in the browser and starts only when you press a button; on a phone it is off until you turn it on.

Fire Extinguisher Simulator — Virtual Fire Extinguisher Training in Your Browser

Most people meet a fire extinguisher for the first time in an emergency. This free fire extinguisher simulator lets you practise first: choose the right extinguisher for the fire in front of you, check it, pull the pin and use the PASS technique on a fire that reacts the way it really would — going out, coming back, or flaring up when the wrong agent hits it. It runs in 3D in a browser on a computer, tablet or phone, with no app or VR headset, and its How it works mode cuts an extinguisher in half so you can watch what the pin, the lever and the valve do.

The fire is a teaching model: it is set so that each extinguisher deals with a fire of the size its rating describes, and each agent works on each fuel as the makers' datasheets and fire-safety guidance say. It shows the right choices and the wrong ones clearly; it is not a prediction of a real fire test.

Types of Fire Extinguishers and Their Uses

Every extinguisher is made for certain kinds of fire, and some are dangerous on others. The table lists the extinguishers in the simulator, the classes each is rated for in the UK and Europe and in the US, the fires on which it makes things worse, and a typical size and rating.

ExtinguisherUse on (UK & Europe)Use on (US)Never use onSize · rating (UK & Europe)Size · rating (US)
Water jet / Water (stored pressure)Class AClass AFlammable liquid, Combustible metal, Live electrical equipment, Cooking oil9 L · 21A2.5 gal · 2-A
Water spray with additiveClass AClass AFlammable liquid, Combustible metal, Live electrical equipment, Cooking oil6 L · 27A6 L · 27A
Water mistClass A, Electrical, Class FClass A, Class C, Class KCombustible metal6 L · 13A 40F2.5 gal · 2-A:C
AFFF foam / AR-AFFF foamClass A, Class BClass A, Class BCombustible metal, Live electrical equipment, Cooking oil6 L · 21A 144B2.5 gal · 3-A:20-B
CO₂ / Carbon dioxide (CO₂)Class B, ElectricalClass B, Class CCombustible metal, Cooking oil2 kg · 34B5 lb · 5-B:C
ABC dry powder / ABC dry chemicalClass A, Class B, Class C, ElectricalClass A, Class B, Class C—6 kg · 43A 233B C5 lb · 2-A:10-B:C
BC powder / BC dry chemicalClass B, Class C, ElectricalClass B, Class C—5.5 lb · 40-B:C5.5 lb · 40-B:C
Metal-fire powder (Class D) / Class D (sodium chloride)Class DClass D—9 kg · D30 lb · D
Wet chemical / Class K wet chemicalClass A, Class FClass A, Class KCombustible metal, Live electrical equipment6 L · 13A 75F6 L · 2-A:K
Clean agent (FK-5-1-12) / Clean agent (Halotron I)Class B, ElectricalClass B, Class CCombustible metal6 kg · 34B5 lb · 5-B:C
Lithium-ion (AVD)Class A, Lithium-ionClass A, Lithium-ionCombustible metal, Live electrical equipment, Cooking oil6 L · 13A6 L · A (UL listed)
Fire blanketClass FClass K—1.2 × 1.2 m · BS EN 18691.2 × 1.2 m · BS EN 1869

Fire Extinguisher Colour Codes

In the UK and Europe (BS EN 3) every extinguisher body is red, with a coloured band naming the agent. In the US nearly every extinguisher is red all over, so the only way to tell them apart is the label: its name, UL rating and pictographs.

ExtinguisherUK & Europe (BS EN 3): red body with aUS: red body, read the label
Water jetRed bandWater (stored pressure) · 2-A
Water spray with additiveRed bandWater spray with additive · 27A
Water mistWhite bandWater mist · 2-A:C
AFFF foamCream bandAR-AFFF foam · 3-A:20-B
CO₂Black bandCarbon dioxide (CO₂) · 5-B:C
ABC dry powderBlue bandABC dry chemical · 2-A:10-B:C
BC powderBlue bandBC dry chemical · 40-B:C
Metal-fire powder (Class D)Blue bandClass D (sodium chloride) · D
Wet chemicalYellow bandClass K wet chemical · 2-A:K
Clean agent (FK-5-1-12)Green bandClean agent (Halotron I) · 5-B:C
Lithium-ion (AVD)White bandLithium-ion (AVD) · A (UL listed)
Fire blanketRed wall caseFire blanket · BS EN 1869

Classes of Fire

Fires are grouped by what is burning. The letters differ between the two systems: a cooking-oil fire is Class F in Europe and Class K in the US, and a gas fire is Class C in Europe but Class B in the US. Europe gives electrical fires no letter at all.

What is burningUK & EuropeUSRight extinguishersDangerous on it
Wood, paper and cardboardClass AClass AWater jet, Water spray with additive, Water mist, AFFF foam, ABC dry powder, Wet chemical, Lithium-ion (AVD)—
Flammable liquid (petrol, solvent)Class BClass BAFFF foam, CO₂, ABC dry powder, BC powder, Clean agent (FK-5-1-12)Water jet, Water spray with additive
Flammable gas (propane)Class CClass BABC dry powder, BC powder—
Combustible metal (magnesium swarf)Class DClass DMetal-fire powder (Class D)Water jet, Water spray with additive, Water mist, AFFF foam, CO₂, Wet chemical, Clean agent (FK-5-1-12), Lithium-ion (AVD)
Live electrical equipmentElectricalClass CWater mist, CO₂, ABC dry powder, BC powder, Clean agent (FK-5-1-12)Water jet, Water spray with additive, AFFF foam, Wet chemical, Lithium-ion (AVD)
Cooking oil (deep-fat fryer)Class FClass KWater mist, Wet chemical, Fire blanketWater jet, Water spray with additive, AFFF foam, CO₂, Lithium-ion (AVD)
Lithium-ion batteryLithium-ionLithium-ionLithium-ion (AVD)—

The PASS Technique

Pull the pin, Aim low at the base of the fire, Squeeze the lever, Sweep from side to side. Before that, raise the alarm, make sure your exit is behind you, and test-squirt briefly away from the fire. Afterwards, back away facing the fire: it can flare up again. An extinguisher empties in seconds, so short, aimed bursts at the base go further than a long spray at the flames.

How a Fire Extinguisher Works

A fire needs heat, fuel, oxygen and a chemical chain reaction — the fire tetrahedron. Water cools; foam and CO₂ smother; dry powder breaks the chain reaction; wet chemical cools burning oil and forms a soapy crust over it. In a stored-pressure extinguisher the agent shares the shell with nitrogen, which drives it up the dip tube as soon as the valve opens, and the gauge shows that pressure. A cartridge-operated extinguisher is unpressurised until a striker punctures a gas cartridge inside it. A CO₂ extinguisher holds liquid CO₂ under its own pressure and has no gauge; it is checked by weighing.

Electrical, Kitchen, Lithium-Ion and Gas Fires

Electrical: water and foam conduct, so on live equipment they can shock you. Isolate the power if it is safe to, and use CO₂ or powder. Kitchen: never put water on burning oil — it flashes to steam and throws the oil out as a fireball. Turn the heat off and use a wet chemical extinguisher or a fire blanket. Lithium-ion: for an e-bike or e-scooter battery, get out and call the fire service; small packs can be cooled with an AVD extinguisher. Gas: shut the supply off and let the flame burn out; putting it out with gas still flowing leaves an explosive cloud.

Inspection and Servicing

In the US, OSHA requires a visual check every month and a maintenance check every year, plus a hydrostatic test every 5 or 12 years depending on the type. In the UK, BS 5306-3 calls for a service by a competent person at least once a year. Between services, anyone can check that the extinguisher is in place, the pin and seal are intact and the gauge needle is in the green.

Who Uses This Simulator?

Employers and safety officers running annual fire awareness, fire wardens and marshals, apprentices and students on workshop and vocational safety courses, teachers, and anyone who wants to know which extinguisher to grab before they need one. It is not a substitute for hands-on training: in the US, OSHA 29 CFR 1910.157(g) requires employers to train employees who are expected to use extinguishers, on hire and every year, and local law sets similar duties elsewhere.

Frequently Asked Questions

What are the main types of fire extinguisher?

The common types are water, foam, dry powder, CO2 and wet chemical, plus specialist ones: water mist, Class D powder for metals, clean agent and AVD for lithium-ion batteries. Each is rated for certain classes of fire, and using the wrong one can make a fire worse.

Which fire extinguisher is used on an electrical fire?

Use CO2 or dry powder, which do not conduct electricity, and isolate the power first if it is safe to. Never use water or foam on live equipment. A water mist extinguisher may only be used if it has passed the 35 kV dielectric test, at least 1 m away, on equipment up to 1000 V.

What does PASS stand for in fire extinguisher use?

Pull the pin, Aim at the base of the fire, Squeeze the lever, Sweep from side to side. Before you start, raise the alarm and keep your exit behind you; afterwards, back away facing the fire.

Can you put water on a burning deep-fat fryer?

No. Water turns to steam under the hot oil and throws it out as a fireball. Switch the heat off if you can, then use a wet chemical extinguisher (Class F in Europe, Class K in the US) or lay a fire blanket over the pan and leave it there. The oil re-ignites by itself above about 392 degrees C.

How do you put out a lithium-ion battery fire?

For an e-bike, e-scooter or other large battery, get out, close the door and call the fire service: the cells keep venting and re-igniting. A small pack, such as a power-tool battery, can be cooled with an AVD extinguisher; the 6 L unit is rated for packs of 250 to 500 Wh.

How often must fire extinguishers be inspected?

In the US, OSHA requires a visual inspection every month and a maintenance check every year, with hydrostatic tests every 5 or 12 years depending on the type. In the UK, BS 5306-3 calls for a service by a competent person at least once a year.

Can a fire extinguisher simulator replace real training?

No. A simulator is practice for choosing the right extinguisher and learning the drill. It does not replace hands-on training with a real extinguisher, which OSHA 29 CFR 1910.157(g) requires on hire and at least once a year.

Explore Related Simulators

Sources

Every figure in the simulator comes from a published source: makers' datasheets, standards and fire-safety guidance. They are listed here by their short codes.

3D Model Credits

The workshop's furniture and machines are openly licensed 3D models, simplified and refitted for this simulator. Under CC BY 4.0: Old Work Bench by Oliver Triplett; Lathe Machine by ridhobahri; Electrical Distribution Cabinet by fdgasd7; Kitchen Counter by FordVFX; city E-bike by rummsfeld (licence: CC BY 4.0). Shelves, drill, hand truck, power box, steel shelving, tool chest, tool cart and toolbox are CC0 models from Poly Haven.

Updated