MechSimulator

Multimeter Simulator

Digital & analog meters on a real bench, in 3D — Simulate • Explore • Practice • Quiz

Mode
Display Controls
Help
Task

    Σ What the meter is doing — from the set-up on screen
    User Guide — Multimeter Simulator
    1 Overview

    A bench with six circuits and two meters: a digital multimeter (6000 counts, true RMS, autoranging) and an analog multimeter (VOM, 20 kΩ/V). The meter is solved as part of the circuit, so what it reads is what a real meter would read, including its own effect on the circuit. It has four modes: Simulate, Explore, Practice and Quiz.

    2 Getting Started

    Pick a circuit in the bar above the picture. To place a probe, click its chip at the top right of the picture (or the probe itself), then click a gold test point; the other probe is selected next. You can also drag a probe onto a point, or choose its point from the Probes lists in the meter panel. The meter panel beside the picture does everything the meter’s face does in one click: the function dial, the jack for the red lead (the black lead always stays in COM), SELECT (Hz on V~, continuity on the diode position, AC on the current positions), RANGE (leaves autorange), HOLD (freezes the display) and REL (subtracts the reading on screen). The dial, buttons and jacks on the drawn meter work too, and [ and ] turn the dial when the picture has focus.

    The page opens in the 3D view on a computer or tablet and in 2D on a phone. In 3D every test point carries a marker you can click even when a part hides it; drag empty space to turn the view, double-click to close in, and use Bench, Board, Meter and + / − in the bar under the picture. The 2D | 3D switch is at the left of that bar and the page remembers your choice; ?view=2d or ?view=3d on a link opens a particular view.

    3 The six circuits
    • Batteries: a 9 V battery, a fresh and a flat AA cell and a 12 V car battery.
    • Voltage dividers: 4.7 kΩ / 10 kΩ and 1 MΩ / 1 MΩ on a 12.00 V supply. Point B shows how much a meter loads a high-resistance circuit.
    • LED circuit: 9 V, a switch, link J1 (click it to take it out and measure current in series), 470 Ω and a red LED that lights with its real current.
    • AC circuit: a 12 V transformer or a function generator (square or triangle wave) feeding a 10 Ω resistor and a lamp, at 50 or 60 Hz.
    • Component tray: four resistors with their colour bands and real values inside ±5 %, a 1N4148 diode, a red and a green LED, a good and a blown fuse, a cold lamp, a switch and a wire.
    • Find the fault: a lamp circuit with a hidden fault. Measure, then name it.

    Each circuit has tasks. The task card under the picture lists the steps of the one you choose (meter, jack, dial, black probe, red probe) and ticks each as you do it; click a step to be shown the control it needs. ▶ Show me how does the selected task on screen, step by step; touching anything stops it.

    4 Mistakes the simulator lets you make

    Leave the red lead in a current jack and probe a battery, and the fuse blows (Replace fuse in the meter panel). Measure ohms on a powered circuit and the reading is meaningless (the meter warns you). Reverse the leads and the digital meter shows a minus sign while the analog needle kicks against its left stop. Overrange shows OL, or the needle pinned at the right.

    5 The analog meter

    Turn the range switch to a DC V, DC A, AC V or Ω range. Read one linear scale and multiply by the range ÷ the scale end, or the Ω scale × the range. Move the pointer across the meter to see the needle’s reflection move in the mirror strip (parallax). On Ω, touch the tips together and drag the 0Ω ADJ knob up or down (or the 0Ω ADJ slider in the meter panel) until the needle sits on 0; choose a worn ohms cell in the meter panel to see why this matters. The black lead is the + of the meter’s cell on Ω.

    6 Explore, Practice & Quiz

    Explore has sixteen cards in four groups: Using the meter, Inside the meter, Analog meters and Mistakes & safety. Practice has two kinds: Read the analog meter (a range and a needle position on every scale) and Calculations (ten kinds of problem). Quiz asks six questions drawn from a pool of twenty, with the options shuffled, and scores you with up to three stars. Electrical units are the same in every country, so the simulator works in volts, amps and ohms only.

    How to Use a Multimeter — an Interactive Virtual Lab

    A multimeter measures voltage, current and resistance, and on most digital meters continuity, diodes and frequency too. This simulator puts a digital and an analog meter on a bench with real circuits. Every reading is computed with the meter connected, the way it is in a real workshop: a voltmeter that draws current, an ammeter that drops a little voltage, test leads with resistance and fuses that blow. That is the difference between knowing the dial settings and knowing how to measure.

    Where the Leads Go and How to Connect

    To measureDialRed leadConnectCircuit
    DC voltageV⎓V Ωacross the part (parallel)on
    AC voltageV~V Ωacross the part (parallel)on
    Current up to 400 mAmA or µAmA µAin series: open the circuiton
    Current up to 10 AAAin series: open the circuiton
    ResistanceΩV Ωacross the partoff
    Continuity, diodes→| •)))V Ωacross the partoff

    The black lead stays in COM. The mA and A jacks are connected to COM through a fuse and a shunt of a fraction of an ohm whatever the dial says, so a red lead left in one of them turns the meter into a short circuit across anything you probe. In the simulator a 9 V battery probed that way pushes 3.4 A through the 440 mA fuse.

    Meter Loading: Why the Reading Can Be Wrong

    A voltmeter is a resistor across the circuit. A digital meter is about 10 MΩ; an analog meter is 20 kΩ for every volt of its range. Across a low-resistance circuit nobody notices, but across a high-resistance one the meter changes what it measures. Two 1 MΩ resistors on the 12.00 V supply should give 6.00 V at their midpoint (point B in the Voltage dividers circuit):

    MeterInput resistanceReads at BError
    Digital multimeter10 MΩ5.714 V−4.8 %
    Analog, 250 V range5 MΩ5.45 V−9.1 %
    Analog, 50 V range1 MΩ4.00 V−33 %
    Analog, 10 V range200 kΩ1.71 V−71 %

    On an analog meter a higher range can give the more accurate reading, because its input resistance is higher. On the 4.7 kΩ / 10 kΩ divider (point A, 8.163 V) the digital meter reads 8.16 V: its loading there is a few parts in ten thousand.

    True RMS and Average-Responding Meters

    An AC voltmeter must report the RMS value. A true-RMS meter computes it for any waveform. An analog meter, and many cheaper digital ones, measures the average of the rectified signal and multiplies by 1.111, the ratio that is right for a sine. With the function generator on the AC circuit:

    Waveform at S1–S2True RMS (digital)Average-responding (analog)Error
    Sine (transformer)11.85 V11.85 V0 %
    Square, 10 V peak4.369 V4.85 V+11.1 %
    Triangle, 10 V peak2.523 V2.43 V−3.8 %

    Reading an Analog Multimeter

    Read only one linear scale, 0–10, 0–50 or 0–250, and multiply by the range divided by that scale’s end. On the 25 mA range a needle at 160 on the 0–250 scale is 16.0 mA. The ohms scale runs the other way, from ∞ at the left to 0 at full deflection, and is crowded at the left; choose the range that puts the needle near the middle, where the centre value is (20 Ω on ×1, 200 Ω on ×10). Zero the ohms with the probes touching every time you change range, and look straight down so the needle covers its own reflection in the mirror strip.

    Finding a Fault with a Voltmeter

    In a dead series circuit no current flows, so every good part drops nothing and the whole supply appears across the open part. With the power on, measure across the switch, the fuse, the lamp and the return wire in turn: the one that reads 12.6 V is the break. A reading of a few volts across a wire or a terminal points to a corroded, high-resistance joint. The Find the fault circuit hides one of six faults each time.

    Safety: CAT Ratings

    Meters are rated by measurement category under IEC 61010: CAT II for appliances and outlets, CAT III for distribution panels and fixed wiring, CAT IV at the service entrance and outdoors. The rating sets where a meter may be used, not just the highest voltage on the dial. The simulator works only on low-voltage circuits; treat a real mains circuit with the meter, leads and procedure your training requires.

    Who Uses This Simulator?

    Students in physics, electronics and electrical courses; apprentices and trainees in electrical, HVAC, automotive and maintenance trades in the United States, the UK and Europe; and teachers who want a class to make the classic mistakes (the blown fuse, the live-circuit ohms reading, the loaded divider) on a screen before they make them on a bench.

    Frequently Asked Questions

    How do you measure voltage, current and resistance with a multimeter?

    Voltage: red lead in the V jack, dial on V, probes across the part with the circuit running. Current: red lead in the mA or A jack, dial on mA or A, open the circuit and put the meter in series so the current flows through it. Resistance: red lead in the V jack, dial on ohms, circuit switched off, probes across the part (ideally taken out of the circuit). The black lead stays in COM every time.

    Why did my multimeter fuse blow?

    Almost always because the red lead was left in the mA or A jack and the probes were put across a voltage. Those jacks connect to COM through a fuse and a shunt of a fraction of an ohm whatever the dial is set to, so the meter is a short circuit across the source. A 9 V battery pushes over 3 A through a 440 mA fuse.

    How do you read an analog multimeter?

    Read one linear scale (0-10, 0-50 or 0-250) and multiply by the range divided by the scale end, so on the 25 mA range a needle at 160 on the 0-250 scale is 16.0 mA. The ohms scale runs right to left and is multiplied by the range (x1, x10, x1k). Look straight down so the needle hides its reflection in the mirror strip.

    Explore Related Simulators

    Updated