MechSimulator

Nuclear Reactor Simulator

PWR & BWR power plants in 2D & 3D • click any part • chain reaction • Explore • Practice • Quiz

Mode
Display Controls
Show
Sound

Scenario
Time
Units

Rod control
Auto holds the coolant temperature on its programme
Slow: the chemical system changes it about 10 ppm a minute
The turbine changes load at 5 % a minute; the reactor follows through its temperature
Thermal power— MW
Electrical output— MW
Reactor power— %
Reactivity— pcm
k-effective—
Reactor period— s
Coolant Tavg— °C
Fuel (average)— °C
Pressurizer pressure— MPa
Xenon-135— pcm
Decay heat— MW
Control rods— % out ·

Control room log

    Where the reactivity comes from

    Every effect adds or removes reactivity; at steady power they add up to zero (k = 1). Values in pcm (1 pcm = 0.001 %).

    User Guide — Nuclear Reactor Simulator
    1 Overview

    The simulator shows how a nuclear power plant works and lets you run one. Choose a pressurized water reactor (PWR) or a boiling water reactor (BWR) with the two large buttons above the drawing. A live model runs underneath: point kinetics with six groups of delayed neutrons, the fuel, coolant and steam temperatures, Doppler and moderator (or void) feedback, boron, xenon-135, decay heat, the control rods and the reactor protection system.

    2 The four views

    Plant 2D is a section through the whole plant, from the containment to the cooling tower, with the water and steam moving and coloured by temperature. On a narrow screen it shows the reactor building and the turbine hall one at a time. Core shows the core from above (assembly power), a side view with the flux along the core, the inside of one fuel assembly, and the six-factor formula split from the live k. Chain reaction shows neutrons and fissions at the scale of the fuel rods. 3D is the whole plant to turn, zoom and cut open. On a computer or tablet the page opens in 3D; on a phone it opens in Plant 2D. Your choice is remembered.

    3 Clicking a part

    Click any part in 2D or 3D, or pick it from ☰ Parts, to open its card: what it is, its function, typical numbers for a real plant and a live reading from the simulation. Next part walks through every part in turn; Show in 3D / 2D finds the same part in the other view.

    4 How it works — the guided tour

    Press 🎓 How it works for a step-by-step walk from fission in the fuel to the cooling tower and the safety systems (9 steps for the PWR, 8 for the BWR). Each step lights up the parts it describes. Use ⏮ ⏭ or the arrow keys to step, ❙❙ to pause and Esc to close.

    5 Running the reactor

    Control rods sets where the rods should go; they move at their real speed (48 steps a minute in the PWR, a notch every 10 s in the BWR). In the PWR, Automatic rod control holds the average coolant temperature on its programme; touching the rod slider switches to Manual. Boron (PWR) changes slowly, 10 ppm a minute. Recirculation flow (BWR) is how a BWR changes power. Turbine load (PWR) changes at 5 % a minute and the reactor follows through its temperature feedback.

    SCRAM drops every rod. The reactor also trips by itself on high flux (109 % PWR, 118 % BWR), a period shorter than 10 s, high or low pressure, low coolant flow, a hot leg near boiling, or a turbine trip. Reset trip latches the shutdown rods again; the control rods stay fully in until you withdraw them.

    6 Scenarios and time

    Seven scenarios: full power; start-up from hot zero power (take the reactor critical); a load change (PWR); a power change by recirculation flow (BWR); a scram with decay heat and xenon; a loss of coolant pumps; and a turbine trip. The Time menu runs the plant from real time up to one hour per second, so you can watch xenon peak about 8 hours after a shutdown.

    7 Readings and the reactivity balance

    The readout cards show the thermal and electrical power, the reactor power (in scientific notation below 0.001 %), the reactivity in pcm, k-effective, the period, the temperatures, the pressure, the xenon worth, the decay heat and the rod position. Where the reactivity comes from shows every contribution — the fuel’s built-in excess against the rods, boron, Doppler, moderator or voids and xenon — and their total. The SI | Imperial switch changes temperatures (°C | °F), pressures (MPa | psia) and flows (kg/s | lb/h).

    8 The chain-reaction view

    Each neutron’s fate — fission, absorbed by a control rod, leaking out, or captured elsewhere — is drawn at its birth from probabilities that make 2.43 × P(fission) equal to k. Use k from the reactor, or try 0.90, 1.00 and 1.10 to see a chain die away, hold steady and grow. Neutrons start fast (red) and slow down in the water (blue); purple ones are delayed neutrons from decaying fission products.

    9 Explore, Practice and Quiz

    Explore has 16 cards in four topics: fission and the chain reaction, controlling the reactor, the power plant, and safety after shutdown. Practice draws from 12 kinds of calculation (fission rate, fuel use, efficiency, reactivity, prompt jump, period, coolant temperature rise, decay heat, the six-factor formula). Quiz asks 10 questions from a pool of 20.

    10 Shortcuts, export and limits

    Right-click the drawing to save an image, copy the readings or restart. PNG saves the current view. The model is for teaching: it treats the core as one point (no spatial flux shape beyond the drawing), the coolant and steam as lumped volumes, and uses representative plant data rather than any one licensed design.

    How Does a Nuclear Reactor Work?

    A nuclear reactor makes heat by splitting uranium nuclei, and a nuclear power plant turns that heat into electricity the same way a coal plant does: with steam, a turbine and a generator. The chain of energy in this nuclear reactor simulator runs in six steps. (1) A slow neutron splits a uranium-235 nucleus (watched nucleon by nucleon in the nuclear fission simulator), releasing about 200 MeV and two or three new neutrons. (2) The water moderator slows those neutrons so that they cause further fissions — a steady chain reaction with k = 1. (3) Control rods and dissolved boron absorb neutrons to set the power. (4) The coolant carries the heat out of the core. (5) That heat makes steam — in a steam generator (PWR) or in the core itself (BWR). (6) The steam turns the turbine and generator, and the condenser and cooling tower get rid of the heat that cannot be turned into work. The simulated PWR makes 3,411 MW of heat and about 1,151 MW of electricity, an efficiency of about 33.7 %.

    Parts of a Nuclear Reactor and Their Functions

    PartWhat it isFunction
    FuelUranium dioxide pellets (3–5 % U-235) in zirconium-alloy rods, bundled into assembliesWhere fission happens; holds the fission products in
    ModeratorOrdinary water around the fuelSlows fast neutrons so they cause more fissions
    Control rodsSilver–indium–cadmium or boron carbide rods (or blades)Absorb neutrons to set the power and shut the reactor down
    CoolantThe same water, pumped through the coreCarries the heat out of the core
    Reactor pressure vesselA steel vessel about 200 mm thickHolds the core and the coolant at high pressure
    Pressurizer (PWR)A vessel of water and steam with heaters and spraysHolds the primary pressure at 15.5 MPa so the coolant does not boil
    Steam generator (PWR)A U-tube heat exchangerBoils clean secondary water using the primary heat
    Reactor coolant / recirculation pumpsLarge centrifugal pumpsDrive the coolant through the core; in a BWR they also set the power
    ContainmentA steel-lined concrete buildingThe last barrier: keeps radioactivity in if a pipe breaks
    Turbine and generatorHigh- and low-pressure turbines on one shaft with the generatorTurn the steam’s energy into electricity
    Condenser and cooling towerA tube heat exchanger under the turbine and a natural-draught towerCondense the exhaust steam and reject the waste heat

    PWR vs BWR

    Both are light-water reactors, moderated and cooled by ordinary water, and together they are over 80 % of the world’s reactors. The numbers below are the simulator’s design values at full power.

    PWRBWR
    Thermal power3,411 MW3,293 MW
    Electrical output1,151 MW1,113 MW
    Reactor pressure15.5 MPa (2,248 psia)7.07 MPa (1,025 psia)
    Coolant temperature291.5 °C in, 325.5 °C out286.5 °C (boiling)
    Steam to the turbineFrom steam generators, 6.99 MPaStraight from the reactor, 7.07 MPa
    CircuitsTwo (primary and secondary)One
    Control rods enter fromThe top, by gravity on a scramThe bottom, driven up hydraulically
    Everyday power controlRods and dissolved boronRods and recirculation flow
    Main feedbackModerator temperature and DopplerSteam voids and Doppler
    Equilibrium xenon at full power−2,156 pcm−2,156 pcm

    Control Rods, Reactivity and the Chain Reaction

    The effective multiplication factor k is the number of neutrons in one generation divided by the number in the generation before. A reactor at steady power is critical, k = 1; it is subcritical below 1 and supercritical above. Engineers usually quote reactivity, ρ = (k − 1)/k, in pcm (10⁻⁵). Prompt neutrons alone would give a generation time of about 20 µs, far too fast to control; but about 0.65 % of the neutrons from U-235 fission are delayed by seconds to a minute, which stretches the response so that a small reactivity of 100 pcm gives a period of about 55 seconds. This simulator solves the point-kinetics equations with all six groups of delayed neutrons, so the period you see is the one the inhour equation predicts.

    Why a Reactor Must Be Cooled After Shutdown

    When the rods drop, the chain reaction stops within seconds, but the radioactive fission products in the fuel keep producing decay heat. The Way–Wigner formula, P/P₀ ≈ 0.0622 [t⁻⁰·² − (t + T)⁻⁰·²], gives about 6 % of full power one second after shutdown, about 1 % after an hour and about 0.4 % after a day — still more than 10 MW for a large plant. That is why the plant keeps its pumps, steam dumps and emergency cooling systems ready long after shutdown. A shutdown also starts the xenon transient: iodine-135 keeps decaying into xenon-135, a strong neutron absorber, which peaks about 8 hours later and can prevent a restart.

    Safety Features

    Western light-water reactors are designed with negative temperature and void coefficients: if the power rises, the hotter fuel and the hotter, less dense water remove reactivity and the rise stops itself. The reactor protection system trips the reactor automatically on high power, a short period, abnormal pressure, low flow or high temperature. Four barriers in series — the fuel pellet, the cladding, the pressure vessel and the containment — hold the radioactivity in, and the emergency core cooling systems can refill and cool the core if coolant is lost. The Chernobyl RBMK, by contrast, had a positive void coefficient.

    Frequently Asked Questions

    How does a nuclear reactor work?

    Uranium-235 nuclei in the fuel split when they absorb slow neutrons, releasing about 200 MeV of energy and two or three new neutrons each. The water moderator slows those neutrons so that they cause more fissions, keeping a steady chain reaction, while control rods absorb neutrons to set the power. The heat from fission is carried away by the coolant and turned into steam, which drives a turbine and generator to make electricity.

    What are the main parts of a nuclear reactor?

    The core contains the fuel assemblies, the control rods and the moderator, inside a thick steel reactor pressure vessel. A pressurized water reactor also has reactor coolant pumps, a pressurizer and steam generators, all inside a concrete containment building. Outside it are the steam turbine, the generator, the condenser and the cooling tower.

    What do control rods do in a nuclear reactor?

    Control rods are made of materials that strongly absorb neutrons, such as silver-indium-cadmium alloy or boron carbide. Inserting them removes neutrons from the chain reaction and lowers the power; withdrawing them raises it. In an emergency shutdown, called a scram, all the rods enter the core in about two seconds and stop the chain reaction.

    What is the difference between a PWR and a BWR?

    In a pressurized water reactor the coolant is kept liquid at about 15.5 MPa and passes its heat to a separate secondary circuit in steam generators, so the turbine steam never touches the core. In a boiling water reactor the water boils in the core at about 7 MPa and the steam goes straight to the turbine. A PWR is controlled with rods and dissolved boron; a BWR with rods and recirculation flow.

    Why does a nuclear reactor need cooling after it shuts down?

    Even after the chain reaction stops, the radioactive fission products in the fuel keep producing decay heat: about 6 percent of full power one second after shutdown, about 1 percent after an hour and still about 0.4 percent after a day. Without cooling, that heat would damage the fuel, which is why reactors have several independent emergency cooling systems.

    Who Uses This Simulator?

    High school physics and chemistry students meeting fission and chain reactions (NGSS HS-PS1-8, GCSE and A-level physics, IB Physics); AP Physics 2 and AP Environmental Science students; undergraduates in introductory nuclear engineering and power-plant engineering; teachers who need an animated, clickable reactor for the classroom; and anyone curious about what happens inside a nuclear power plant.

    Selected References

    J. R. Lamarsh and A. J. Baratta, Introduction to Nuclear Engineering; J. J. Duderstadt and L. J. Hamilton, Nuclear Reactor Analysis; G. R. Keepin, Physics of Nuclear Kinetics; S. Glasstone and A. Sesonske, Nuclear Reactor Engineering; US Nuclear Regulatory Commission, Pressurized Water Reactor Systems and Boiling Water Reactor Systems training manuals; IAPWS-IF97 steam tables.

    Explore Related Simulators

    Follow the steam through its cycle in the Rankine Cycle simulator and compare a fossil-fired plant in the Steam Boiler simulator. See the steam generator’s job in the Heat Exchanger simulator, the coolant pumps in the Centrifugal Pump simulator, and how the generator and the step-up transformer make and send the electricity in the AC Generator and Transformer simulators. Build the nuclei themselves in Build Your Atom, and compare a renewable plant in the Hydroelectric Power Plant simulator.

    Updated